Sept. 13, 2021
Whether you’ve already returned to your workplace or will be heading back to the office eventually, it’s a good idea to ask what steps your employer has taken to improve indoor air quality.
The more time we spend indoors with other people, the more likely we are to breathe each other’s exhaled air — and germs. The vast majority of scientists now agree that the coronavirus is airborne, and infectious droplets can linger in the air, float around the room or build up in spaces with poor air flow, like conference rooms.
While vaccination requirements and masking remain a first line of defense against Covid-19, ventilation improvements in schools and workplaces are essential to stopping the spread of the coronavirus, said Dr. Ashish K. Jha, dean of the Brown University School of Public Health.
In addition to asking questions about ventilation, you should ask about vaccination policies, staggered workdays to reduce capacity, Covid testing plans, mask requirements and how the building is monitoring outside workers, like delivery people and cleaning crews.
Here are six questions you can ask your human resources or facilities office, depending on who handles return-to-office questions at your workplace.
- What improvements have you made to the ventilation system?
Most newer buildings rely on mechanical heating, ventilation and air-conditioning systems, known as HVAC, that use a combination of air filters and outdoor air to dilute and remove viral particles and other pollutants. Buildings can take a number of steps to improve the performance of ventilation systems and increase the amount of fresh air, including:
Improving their MERV ratings
The filters used in ventilation systems have what’s known as a MERV rating (MERV stands for Minimum Efficiency Reporting Values). The higher the rating, the better the filter is at trapping specific types of particles.
Before the pandemic, many buildings used MERV 8 filters, which allow for comfort and energy efficiency but aren’t designed for infection control. New industry guidelines advise buildings to upgrade to at least a MERV 13 filter, which traps 85 percent or more of risky particles. However, not every ventilation system can upgrade to a MERV 13 filter. In some cases, a MERV 11 filter may be the highest grade filter the system can handle.
Disabling demand-controlled ventilation
To save energy, some systems monitor building occupancy based on carbon dioxide levels, which rise when we exhale. When fewer people are in the building, the system reduces the rate of outdoor air. “It’s a way to stop ventilating the space to save money,” said Richard Corsi, incoming dean of the College of Engineering at University of California, Davis. “But after people leave an area, we need to continue to ventilate so we can purge the space of any aerosol particles left in the air.”
Increasing outdoor air
Air quality experts recommend adjusting outdoor air dampers, which are movable plates that can bring in more outside air. This isn’t advised in communities with poor outdoor air quality, such as areas with active wildfires.
- Can the windows be opened?
Some older buildings and classrooms may not have modern ventilation systems, but simply opening windows can improve air quality. A recent study of infected college students in an isolation dormitory at the University of Oregon found that opening a window could reduce the amount of coronavirus in a room by half.
While opening a window can help, the effect is greater if you can cross ventilate by opening windows on different sides of the room. Open windows aren’t practical during cold weather or in areas with poor outdoor air quality. Adding box fans to windows and turning on exhaust fans in kitchen and bathroom areas can also improve ventilation in homes and in buildings without modern systems.
- What is the air change rate?
The air changes per hour, or ACH, number is the industry standard to indicate how often the air in a room is replaced by outdoor air. (Cleaning the air with filters can create the equivalent of air change.) While some experts suggest four to six air changes per hour (that’s fresh or clean air every 10 to 15 minutes), many buildings fall short of that standard. It’s recommended that schools have an ACH of at least 3, but many classrooms are closer to 1.5, experts say. Airplanes and newer hospitals may have anywhere from 10 to 20 air changes per hour. Air change rates or their equivalent can be improved by upgrading the overall ventilation system or filters, increasing the amount of outdoor air (by opening windows or ventilation dampers), adding exhaust fans or by adding portable air filters.
While there’s no magic number for air change rates to avoid Covid-19, the higher the better, said Dr. Corsi.
- Are you using portable air cleaners?
Portable air cleaners equipped with HEPA filters can do a surprisingly good job of removing viral particles from the air, but only if the right machine is used for the size of the space. Look for a machine with a clean air delivery rate, or CADR, of at least 300 cubic feet per minute, and read the manufacturer guidance for choosing room size. You may need more than one machine for a larger space. The Association for Home Appliance Manufacturers has a guide for buying air cleaners.
Adding an air cleaner can partly compensate for a less efficient ventilation system, depending on the size of the room. In some cases, “one of these little portable air cleaners can effectively double the ventilation rate in the classroom,” said Dr. Corsi.
A study in a Melbourne hospital recently showed that adding two portable air cleaners to a patient’s room eliminated 99 percent of aerosols in minutes, reportedly raising the protection level equal to about 30 air changes per hour.
- Who is monitoring air quality?
Carbon dioxide sensors can indicate how well a ventilation system is working. Virus scientists and air quality experts sometimes carry portable CO2 detection devices. Linsey Marr of Virginia Tech, one of the world’s leading experts on viral transmission, has used such a device to check levels at her gym and in grocery stores.
“Carbon dioxide is in our exhaled breath,” said Dr. Marr. “If the levels get high indoors, it means people’s exhaled breath is building up, and that exhaled breath of course could contain virus if someone is infected.”
In general, you don’t want the CO2 number to rise above 800. In gyms, where people are breathing heavily, Dr. Marr advises leaving or masking up if the number goes above 600.
- Does the building rely on unproven technologies?
Many companies are installing what the Environmental Protection Agency calls “emerging technologies,” including one called a needlepoint bipolar ionization system. The system claims to use positive and negative particles to help remove viruses from the air. But many of the world’s leading experts on indoor air quality, including Joseph Allen at Harvard and Shelly Miller at the University of Colorado, Boulder, have questioned the effectiveness of the technology. “There’s a reason you haven’t seen a single indoor air quality expert recommend this technology,” tweeted Dr. Allen.
The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), which makes recommendations about indoor air quality standards, has said that bipolar ionization is one of several unproven technologies. “Convincing, scientifically rigorous, peer-reviewed studies do not currently exist on these emerging technologies,” the group has said.
Despite skepticism about the technology, many workplaces are installing them anyway.
“These companies have done a great job of marketing,” said Dr. Marr. “It makes businesses feel like they’ve done something.”